Specific Program Requirements *These requirements are in addition to the Program Terms and Conditions. | ||
|
1. Please refer to the program guide for additional applicable technical
requirements. 2. Include the manufacturer’s specification sheet with the application package and mail or fax directly to the Commercial/Industrial Market Manager. 3. Incentives for T-5 and T-8 lamps with electronic ballasts are available only for fixtures with a Total Harmonic Distortion of ≤ 20%. 4. All eligible lighting devices must be UL listed. 5. Requirements for CFL fixtures (must meet all requirements):
|
6. Pulse Start Metal Halide (including pole-mounted parking lot
lighting) must have a 12% minimum wattage reduction. 7. T-5 or T-8 Fixtures replacing incandescent or T-12 fluorescent fixtures greater than 250 watt or High Intensity Discharge shall comply as follows: 7.1 T-5 fixtures replacing T-12 fluorescent or incandescent fixtures 250 watts or greater, or HID fixtures shall have a ballast factor greater than or equal to 1.0; have reflectivity greater than or equal to 91%; have a minimum 2 lamps; and be designated as F54T5 HO. 7.2 T-8 fixtures replacing T-12 fluorescent or incandescent fixtures 250 watts or greater, or HID fixtures shall have a ballast factor greater than or equal to 1.14; have reflectivity greater than or equal to 91%; have a minimum of 4 lamps; and be designated as F32T8, minimum 32 watts. 7.3 Incentives for de-lamped T-8 lamps with new reflectors are available only for fixtures with a total Harmonic Distortion of <20%. Electronic ballast replacement required for all eligible de-lamped fixtures. Eligible de-lamping can include reduction in linear lamp feet from existing conditions. For example, 1-8' linear fluorescent lamp can be considered as 2-4' linear lamps. U-bend lamps 4' in total length can be considered as 2-F17/T8 lamps. 7.4 Electronic ballast replacement is necessary for all eligible de-lamped fixtures. 7.5 Reduced wattage T8 (28W/25W 4') (1-4 lamps) retrofit requires lamp and ballast replacement. 8. LED Refrigerated/Freezer Case Lighting must meet NEEP Design Lights Consortium Standards or be on an Energy Star or a SSL Qualified Product list. For new door installations on existing open cases, indicate the number of LED fixtures to be installed. Also indicate "New Door" in the Fixture Type column on the Prescriptive Lighting Worksheet (i.e. New Door 5' LED). | |
Copyright 2001-2012 Globus Electric Inc.
Last Updated For You On:
![]()
This Web-site Designed and Maintained by E&A Marketing. All Rights Reserved.